Line 21: | Line 21: | ||
Different main unit versions use different 3-character prefix. <ref>https://turbo-quattro.com/archive/index.php/t-24737.html</ref> | Different main unit versions use different 3-character prefix. <ref>https://turbo-quattro.com/archive/index.php/t-24737.html</ref> | ||
− | * | + | <div style="column-count:2;-moz-column-count:2;-webkit-column-count:2"> |
− | * BKA = MIB2 | + | * 8VV = MIB2 STD Delphi |
− | * JTH | + | * AW7 = MIB1 Aisin |
− | * | + | * BKA = MIB2 Harman |
− | * YJL | + | * GRO = MIB2 Delphi |
− | * | + | * HHA =?? |
+ | * JTH = MIB2 Harman | ||
+ | * JTB = MIB1/MIB2 High Harman | ||
+ | * PM6 = MIB STD Panasonic | ||
+ | * YJL = MIB2 Harman | ||
+ | * YD5 = MIB STD2 Technisat/Preh | ||
+ | * YD7 = MIB STD2 Preh | ||
+ | </div> | ||
=== Boardbook data path === | === Boardbook data path === |
Revision as of 10:18, 21 August 2020
Purpose
Contents
File names and locations
- /tsd/etc/slist/signed_exception_list.txt
- /HBpersistence/FEC/Exceptionlist.txt
- prodEL.txt
File Content
Fazit IDs
There's a mechanism that can secure the file and prohibit for using it in different device than it's intended to.
Example: VVV-074DD.MM.YYZZZZZZZZ
- VVV = vendor or main unit code name
- DD = production day
- MM = production month
- YY = production year
- ZZZZZZZZ = VCRN
There seems to be a workaround mechanism by replacing characters with ?
. That way we get ???-?????.??.??????????
which in theory should be accepted as valid by main units with different VCRNs and production dates.
Different main unit versions use different 3-character prefix. [1]
- 8VV = MIB2 STD Delphi
- AW7 = MIB1 Aisin
- BKA = MIB2 Harman
- GRO = MIB2 Delphi
- HHA =??
- JTH = MIB2 Harman
- JTB = MIB1/MIB2 High Harman
- PM6 = MIB STD Panasonic
- YJL = MIB2 Harman
- YD5 = MIB STD2 Technisat/Preh
- YD7 = MIB STD2 Preh
Boardbook data path
Destination = "/net/mmx/mnt/boardbook"
SigDestination = "/net/mmx/mnt/boardbook/RSDB"
PPOI data path
Destination = "/net/mmx/mnt/navdb/PersonalPOI"
List of supported FSCs
[SupportedFSC]
fsc = "00030000"
fsc2 = "00040100"
fsc3...
FEC can be provided as a range of values, for example fsc = "02100000;0210003F"
.
Signature
[Signature]
signature1 = ...
Parsing
Process tsd.mibstd2.system.swap
checks the file, compares production date, VCRN, signature. If it's all OK, then it passes listed FEC codes ad valid.